Key takeaways
- Equipment needs calibration, maintenance, repair, training and decommissioning, so compare total cost of ownership, not only price. [2]
- WHO technical specifications can support tendering and purchasing, and planning maintenance. [1]
- For blood pressure monitors, ask for clinical validation to ISO 81060 Part 2. [3]
- Pulse oximeter accuracy can be affected by skin pigmentation, poor circulation and nail polish, so ask for clinical test data. [5]
- For glucose meters, ISO 15197:2013 sets accuracy criteria, and strips are an ongoing cost. [7]
Think beyond the purchase price
The term equipment refers to a medical device that requires calibration, maintenance, repair, user training and decommissioning. [2] That is why buying on price alone is risky. A guide from Management Sciences for Health lists local servicing and spare parts, and local training in use and maintenance, among the main criteria for selecting equipment, and it says specifications should be written with technical staff. [2] WHO's technical specifications give basic, appropriate specifications for low and middle income settings and can be used for tendering, purchasing and planning maintenance. [1]
What to specify, device by device
| Device | State in your request |
|---|---|
| Blood pressure monitors | Manual or automated, upper arm cuff, cuff sizes needed, power source, validation protocol |
| Pulse oximeters | Fingertip or handheld, adult and paediatric probes, power, clinical test data |
| Thermometers | Digital or infrared, measurement range, stated accuracy, probe covers, battery type |
| Glucose meters | ISO 15197:2013 evidence, test strips and lancets per meter, strip expiry, sample volume |
Ask each supplier to quote the full set, including cuffs, probe covers, strips, batteries and chargers, so that offers compare on the same basis. For thermometers, the stated accuracy range is the main figure to compare, so ask how the device should be checked over time. For blood pressure monitors, ask for the range of cuff sizes your patients need.
Asking for evidence of accuracy
Blood pressure monitors
Clinically validated automated arm cuff devices are recommended, and new validation studies should follow ISO 81060 Part 2:2018, often called the universal standard. [3] Several lists of validated devices exist, and STRIDE BP covers blood pressure monitors, glucose monitors and pulse oximeters internationally. [4]
Pulse oximeters
The US FDA warns that readings can be affected by skin pigmentation, poor circulation, skin thickness, skin temperature, tobacco use and nail polish, and that readings should be treated as estimates. [5] It has also proposed that clinical testing include a diversely pigmented group of at least 150 participants. [6] Because many users in Kenya have darker skin, ask manufacturers for test data that covers a range of pigmentation.
Glucose meters
ISO 15197:2013 requires at least 95 percent of results to fall within 15 mg/dl of a laboratory reference below 100 mg/dl, or within 15 percent at 100 mg/dl and above, and 99 percent within zones A and B of the consensus error grid. [7] Ask whether the meter was tested against it, and for the price and expiry of strips.
Warranty, service and training
A WHO laboratory guidance document lists warranty, technical support from the manufacturer and service contracts among the criteria for selecting equipment, and it suggests asking for installation and staff training, an operator's manual and, where possible, a trial period. [8] Put these into your request:
- Warranty length, and what it covers
- Local service, spare parts and calibration arrangements
- Operator training and manuals
- Registration status in Kenya where it applies, and manufacturer documents [9]
Quantities and requesting a quotation
Count your points of use, then add spares for repair downtime, in a number agreed with your clinical or biomedical lead. As an illustration with made up numbers, 8 consulting and ward points plus 2 spares means 10 units. Add consumables such as cuffs, probe covers and strips to the same order.
Blood pressure machines, digital thermometers, pulse oximeters and blood sugar meters are examples of diagnostic devices on our products page. Send your specification through the contact page and follow our quotation guide. Related guides cover catheters and tubing and waste management supplies.
Example request: "Please quote for 10 automated upper arm blood pressure monitors with adult and large cuffs, 10 fingertip pulse oximeters and 6 glucose meters with 50 strips each. Please state validation evidence, warranty and local service. Delivery to Kisumu."
Related reading: how to maintain clinic equipment after you buy it and equipping a first aid room.
Frequently asked questions
Ask for clinical validation to ISO 81060 Part 2, ideally the 2018 version, and check whether the model appears on a validated device list.
Accuracy can be affected by skin pigmentation and other factors. Treat readings as estimates, and ask manufacturers for clinical test data that includes darker skin tones.
Yes. Test strips and lancets are ongoing costs, and strips have expiry dates, so compare the cost per test as well as the meter price.
These are examples of diagnostic devices we supply. Send your specification and quantities and we will confirm availability with your quotation.
Note: this guide supports purchasing decisions. It is not clinical or infection control advice. Follow your facility's infection prevention and control policy and current Ministry of Health guidance.
Cloaked Innovations Limited supplies non-pharmaceutical consumables and medical equipment to institutions across Kenya. Visit our homepage or read about us to learn more.
Sources
- World Health Organization. User guide: WHO technical specification for medical devices. https://www.who.int/publications/m/item/user-guide-who-technical-specification-for-medical-devices
- Management Sciences for Health. Managing drug supply, chapter 47: medical equipment and supplies. https://msh.org/wp-content/uploads/2013/04/mds3-ch47-labservices-mar2012.pdf
- Clinically validated blood pressure measuring devices and validation lists. PMC9957729. https://pmc.ncbi.nlm.nih.gov/articles/PMC9957729
- Hypertension Canada blood pressure device recommendation listing (review of validated device lists). PMC8030023. https://pmc.ncbi.nlm.nih.gov/articles/PMC8030023
- US Food and Drug Administration. FDA In Brief: FDA warns about limitations and accuracy of pulse oximeters. 19 February 2021. https://www.fda.gov/news-events/fda-brief/fda-brief-fda-warns-about-limitations-and-accuracy-pulse-oximeters
- CNN via KEYT. FDA issues draft guidance to improve accuracy of pulse oximeters for people with darker skin tones. https://keyt.com/?p=1213313
- Accuracy criteria of ISO 15197:2013 for blood glucose monitoring systems. PMC9445334. https://pmc.ncbi.nlm.nih.gov/articles/PMC9445334/
- World Health Organization. Guidance on specifications for TB laboratory supply, annex A3. https://extranet.who.int/lqsi/sites/default/files/attachedfiles/Guidance_on_specifications_for_TB_lab_supply_A3.pdf
- Republic of Kenya. The Pharmacy and Poisons (Registration of Health Products and Technologies) Rules, 2022. https://faolex.fao.org/docs/pdf/ken212581.pdf